Downloads

Zhang, J. (2026). Design and Simulation of Combined Coriolis and Thermal Flow Sensors. Innovations in Applied Engineering and Technology, 5(1), 0010. https://doi.org/10.62836/iaet.v5i1.0010

Design and Simulation of Combined Coriolis and Thermal Flow Sensors

Liquid flow measurement is important in automated systems that need to deliver repeatable amounts of liquid. A dispenser may need to handle both rapid filling and slow delivery, making measurement over a wide flow range important. This study combines Coriolis and thermal flow estimates to extend that range and improve precision where both sensors are useful. A common signal model links vibration timing difference and temperature rise to volume flow, while accounting for heating and tube pressure loss. With reference water, 10 W of effective heating and 15-reading averages, the predicted range meeting a 10% relative-standard-deviation target is 12.91–92.30 mL/s for Coriolis and 0.240–23.96 mL/s for thermal sensing. Together, the sensors cover a predicted measurement range of 0.240–92.30 mL/s (a maximum-to-minimum flow ratio of approximately 385:1). Simulations then evaluated the rules for selecting or combining the sensor estimates at 75 selected flow rates within this predicted range. All four rules, including switching, gave relative root mean squared error (RMSE) below 10% at these points. At 20 mL/s, uncertainty weighting reduces RMSE by 16.7% relative to the better individual sensor. Blending and joint likelihood give similar results. Tests with five sets of liquid properties show how specific heat capacity, density and viscosity change the measurement range and calibration requirements. Longer averaging reduces random scatter, but an incorrect calibration can leave repeated estimates centred on the wrong flow.

Coriolis flow sensing thermal flow sensing sensor fusion uncertainty calibration simulation

References

  1. Bronkhorst. Coriolis Flow Meter Working Principle. Available online: https://www.bronkhorst.com/knowledge-base/coriolis-flow-meter-working-principle/ (accessed on 23October 2026).
  2. Bronkhorst. How Does a Thermal Mass Flow Meter Work? Available online: https://www.bronkhorst.com/knowledge-base/thermal-mass-flow-measurement/ (accessed on 23October 2026).
  3. Lötters JC, Lammerink TSJ, Groenesteijn J, et al. Integrated Thermal and Microcoriolis Flow Sensing System with a Dynamic Flow Range of More Than Five Decades. Micromachines 2012; 3(1): 194–203. https://doi.org/10.3390/mi3010194.
  4. Lyons L, Gibaut D, Clifford P. How to Combine Correlated Estimates of a Single Physical Quantity. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 1988; 270(1): 110–117. https://doi.org/10.1016/0168-9002(88)90018-6.
  5. Wang T, Baker R. Coriolis Flowmeters: A Review of Developments over the Past 20 Years, and an Assessment of the State of the Art and Likely Future Directions. Flow Measurement and Instrumentation 2014; 40: 99–123. https://doi.org/10.1016/j.flowmeasinst.2014.08.015.
  6. Kolhe V, Pawar S, Chaudhari V, et al. Parameter Optimization of Coriolis Mass Flow Meter in Laminar Flow Regime Using Doe-Taguchi Method. Journal of Thermal Engineering 2023; 9(4): 1026–1040. https://doi.org/10.18186/thermal.1335677.
  7. U.S. Department of Energy. DOE Fundamentals Handbook: Thermodynamics, Heat Transfer, and Fluid Flow; Volume 2; DOE-HDBK-1012/2-92; U.S. Department of Energy: Washington, DC, USA, 1992. Available online: https://www.energy.gov/sites/default/files/2026-04/DOE-HDBK-1012-92_VOL2.pdf (accessed on 20 November 2026).
  8. Joint Committee for Guides in Metrology (JCGM). Evaluation of Measurement Data—Guide to the Expression of Uncertainty in Measurement; JCGM 100:2008; JCGM: Sèvres, France, 2008. https://doi.org/10.59161/JCGM100-2008E.
  9. U.S. Department of Energy. DOE Fundamentals Handbook: Thermodynamics, Heat Transfer, and Fluid Flow; Volume 3; DOE-HDBK-1012/3-92; U.S. Department of Energy: Washington, DC, USA, 1992. Available online: https://www.energy.gov/documents/doe-hdbk-1012-92vol3 (accessed on 20 November 2026).
  10. Haaland SE. Simple and Explicit Formulas for the Friction Factor in Turbulent Pipe Flow. Journal of Fluids Engineering 1983; 105(1): 89–90. https://doi.org/10.1115/1.3240948.
  11. Cowan G. Statistics (Chapter 40). Available online: https://pdg.lbl.gov/2024/reviews/rpp2024-rev-statistics.pdf (accessed on 20 November 2026).
  12. Lemmon EW, Bell IH, Huber ML, et al. Thermophysical Properties of Fluid Systems. In NIST Chemistry WebBook; NIST Standard Reference Database Number 69; National Institute of Standards and Technology: Gaithersburg, MD, USA. Available online: https://webbook.nist.gov/chemistry/fluid/ (accessed on 20 November 2026).
  13. Joint Committee for Guides in Metrology (JCGM). Evaluation of Measurement Data—Supplement 1 to the Guide to the Expression of Uncertainty in Measurement—Propagation of Distributions Using a Monte Carlo Method; JCGM 101:2008; JCGM: Sèvres, France, 2008. https://doi.org/10.59161/JCGM101-2008.
  14. Minim LA, Coimbra JSR, Minim VPR, et al. Influence of Temperature and Water and Fat Contents on the Thermophysical Properties of Milk. Journal of Chemical & Engineering Data 2002; 47(6): 1488–1491. https://doi.org/10.1021/je025546a.
  15. Domalski ES, Hearing ED. Condensed Phase Heat Capacity Data. In NIST Chemistry WebBook; NIST Standard Reference Database Number 69; National Institute of Standards and Technology: Gaithersburg, MD, USA. Available online: https://doi.org/10.18434/T4D303 (accessed on 20 November 2026).
  16. NIST Chemistry WebBook. Ethanol. Available online: https://webbook.nist.gov/cgi/cbook.cgi?ID=C64175&Mask=2 (accessed on 25 October 2026).
  17. NIST Chemistry WebBook. Glycerin (Glycerol). Available online: https://webbook.nist.gov/cgi/cbook.cgi?ID=C56815&Mask=2 (accessed on 25 October 2026).
  18. ExxonMobil. White Oils Products. Available online: https://www.exxonmobil.com/en/whiteoil/products(accessed on25 October 2026).
  19. Taylor BN, Kuyatt CE. Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results; NIST Technical Note 1297; National Institute of Standards and Technology: Gaithersburg, MD, USA, 1994. https://doi.org/10.6028/nist.tn.1297.
  20. Gelderblom H, Van Der Horst A, Haartsen JR, et al. Analytical and experimental characterization of a miniature calorimetric sensor in a pulsatile flow. Journal of Fluid Mechanics 2011; 666: 428–444. https://doi.org/10.1017/s0022112010004234.

Supporting Agencies

  1. Funding: This research received no external funding.